Violation Detail
Standard Cited: 19100147 C04 II B The control of hazardous energy (lockout/tagout).
This violation item has been deleted.
Inspection Nr: 456613.015
Citation: 01001
Citation Type: Serious
Abatement Date: 08/14/2012
Initial Penalty: $5,000.00
Current Penalty: $0.00
Issuance Date: 07/31/2012
Nr Instances: 1
Nr Exposed: 1
Related Event Code (REC):
Gravity: 5
Report ID: 0625400
Contest Date: 09/20/2012
Final Order: 03/04/2013
Emphasis:
| Type | Latest Event | Event Date | Penalty | Abatement Due Date | Citation Type | Failure to Abate Inspection |
|---|---|---|---|---|---|---|
| Penalty | F: Formal Settlement | 03/04/2013 | $0.00 | 08/14/2012 | Serious | |
| Penalty | C: Contested | 09/20/2012 | $5,000.00 | 08/14/2012 | Serious | |
| Penalty | Z: Issued | 07/31/2012 | $5,000.00 | 08/14/2012 | Serious |
Text For Citation: 01 Item/Group: 001 Hazard:
29 CFR 1910.147(c)(4)(ii)(B): The energy control procedures did not clearly and specifically outline the steps for shutting down, isolating, blocking and securing machines or equipment to control hazardous energy. On or about May 30, 2012, procedures were not developed to control the hazardous stored energy on the Stock Gravimetric Feeder where an employee was required to remove the load span roller, exposing the employee to the hazard of being caught-in a pinch point.