Violation Detail
Standard Cited: 19260451 B04 General requirements.
Inspection Nr: 448073.015
Citation: 01001B
Citation Type: Serious
Abatement Date: 09/14/2012 5
Initial Penalty: $0.00
Current Penalty: $0.00
Issuance Date: 09/13/2012
Nr Instances: 1
Nr Exposed: 2
Related Event Code (REC):
Gravity: 5
Report ID: 0317000
Contest Date:
Final Order: 11/01/2012
Emphasis:
Type | Latest Event | Event Date | Penalty | Abatement Due Date | Citation Type | Failure to Abate Inspection |
---|---|---|---|---|---|---|
Penalty | Z: Issued | 09/13/2012 | $0.00 | 09/14/2012 | Serious |
Text For Citation: 01 Item/Group: 001B Hazard:
29 CFR 1926.451(b)(4): Each end of a platform, unless cleated or otherwise restrained by hooks or equivalent means, shall extend over the centerline of its support at least 6 inches (15 cm). a) Jobsite: 1824 Christian St, Philadelphia, PA. - On or about 5/29/12, the end of the platforms on the supported tubular welded frame scaffold did not extended over the centerline of their support by at least 6 inches. Employees were performing masonry operations from the 3rd working platform, approximately 18 ft. above ground level.