Violation Detail
Standard Cited: 19260451 C01 II General requirements.
Inspection Nr: 432371.015
Citation: 01003
Citation Type: Serious
Abatement Date: 06/27/2012 2
Initial Penalty: $1,200.00
Current Penalty: $600.00
Issuance Date: 06/26/2012
Nr Instances: 1
Nr Exposed: 2
Related Event Code (REC):
Gravity: 1
Report ID: 0317500
Contest Date:
Final Order: 07/16/2012
Emphasis:
Type | Latest Event | Event Date | Penalty | Abatement Due Date | Citation Type | Failure to Abate Inspection |
---|---|---|---|---|---|---|
Penalty | I: Informal Settlement | 07/16/2012 | $600.00 | 06/27/2012 | Serious | |
Penalty | Z: Issued | 06/26/2012 | $1,200.00 | 06/27/2012 | Serious |
Text For Citation: 01 Item/Group: 003 Hazard:
29 CFR 1926.451(c)(1)(ii): Guys, ties, and/or braces were not installed according to the scaffold manufacturer's recommendations or at the closest horizontal member to the 4:1 height and repeated vertically at locations of horizontal members every 20 feet (56.1 m) or less thereafter for scaffolds 3 feet ((0.91 m) wide or less, and every 26 feet (7.9 m) or less therafter for scaffolds greater than 3 feet (0.91m) wide. (a) Jobsite- Beaver Street, Sewickley, PA: On or about May 16, 2012 employees working on a scaffold measuring approximately 35 feet high did not secure the scaffold to the building.