Violation Detail
Standard Cited: 19100424 C04 I SCUBA diving.
Inspection Nr: 392982.015
Citation: 01002B
Citation Type: Serious
Abatement Date: 10/18/2012 2
Initial Penalty: $0.00
Current Penalty: $0.00
Issuance Date: 10/17/2012
Nr Instances: 1
Nr Exposed: 1
Related Event Code (REC): A
Gravity: 10
Report ID: 0625400
Contest Date:
Final Order: 10/31/2012
Emphasis:
| Type | Latest Event | Event Date | Penalty | Abatement Due Date | Citation Type | Failure to Abate Inspection |
|---|---|---|---|---|---|---|
| Penalty | I: Informal Settlement | 10/31/2012 | $0.00 | 10/18/2012 | Serious | |
| Penalty | Z: Issued | 10/17/2012 | $0.00 | 10/18/2012 | Serious |
Text For Citation: 01 Item/Group: 002B Hazard:
29 CFR 1910.424(c)(4)(i): A diver-carried reserve breathing gas supply consisting of either a manual reserve (j valve) or an independent reserve cylinder with a separate regulator or connected to the underwater breathing apparatus was not provided for each diver: On or about April 18, 2012, a diver was performing SCUBA diving operations approximately 37 feet underwater inside the Lake O.H. Ivie Pump Intake Structure without a reserve breathing gas supply. Pursuant to 29 C.F.R. 1903.19, within ten (10) calendar days of the date of this citation, the employer must submit documentation showing that it is in compliance with the standard, including describing the steps that it is taking to ensure that all SCUBA divers are provided with a reserve breathing gas supply.