Violation Detail
Standard Cited: 19100424 C02 SCUBA diving.
Inspection Nr: 392982.015
Citation: 01002A
Citation Type: Serious
Abatement Date: 10/18/2012 2
Initial Penalty: $2,800.00
Current Penalty: $0.00
Issuance Date: 10/17/2012
Nr Instances: 1
Nr Exposed: 1
Related Event Code (REC): A
Gravity: 10
Report ID: 0625400
Contest Date:
Final Order: 10/31/2012
Emphasis:
| Type | Latest Event | Event Date | Penalty | Abatement Due Date | Citation Type | Failure to Abate Inspection |
|---|---|---|---|---|---|---|
| Penalty | I: Informal Settlement | 10/31/2012 | $0.00 | 10/18/2012 | Serious | |
| Penalty | Z: Issued | 10/17/2012 | $2,800.00 | 10/18/2012 | Serious |
Text For Citation: 01 Item/Group: 002A Hazard:
29 CFR 1910.424(c)(2): Diver was not line tended from the surface or accompanied by another diver in the water in continuous visual contact during SCUBA diving operation: On or about April 18, 2012, a diver was performing SCUBA diving operations approximately 37 feet underwater inside the Lake O.H. Ivie Reservoir Pump Intake Structure without ensuring a tending line was secured or another diver was available in the water. Pursuant to 29 C.F.R. 1903.19, within ten (10) calendar days of the date of this citation, the employer must submit documentation showing that it is in compliance with the standard, including describing the steps that it is taking to ensure that all SCUBA divers are line tended or provided another diver in the water.