Violation Detail
Standard Cited: 19100212 A05 General requirements for all machines.
Inspection Nr: 332548.015
Citation: 01011
Citation Type: Serious
Abatement Date: 07/04/2012 2
Initial Penalty: $2,100.00
Current Penalty: $1,575.00
Issuance Date: 06/19/2012
Nr Instances: 1
Nr Exposed: 4
Related Event Code (REC):
Gravity: 1
Report ID: 0830500
Contest Date:
Final Order: 06/28/2012
Emphasis:
| Type | Latest Event | Event Date | Penalty | Abatement Due Date | Citation Type | Failure to Abate Inspection |
|---|---|---|---|---|---|---|
| Penalty | I: Informal Settlement | 06/28/2012 | $1,575.00 | 07/04/2012 | Serious | |
| Penalty | Z: Issued | 06/19/2012 | $2,100.00 | 07/05/2012 | Serious |
Text For Citation: 01 Item/Group: 011 Hazard:
29 CFR 1910.212(a)(5): When the periphery of the blades of a fan was less than seven (7) feet above the floor or working level, the blades were not guarded. The guard had openings larger than one-half (1/2) inch. (a) Roggen Farms, 36401 Weld County Road 24 1/2, Roggen, CO 80652: On an before April 11, 2012, the exposing employer did not effectively guard the blades of a fan located in the electrical room whose lower openings where at approxmately 6 feet, with openings larger than 1/2 an inch. Conditions exposed employees to the dangers on contact with the fan blades while the fan was in operation.
Translate