Violation Detail
Standard Cited: 19100147 C06 I The control of hazardous energy (lockout/tagout).
This violation item has been deleted.
Inspection Nr: 306798869
Citation: 01001B
Citation Type: Serious
Abatement Date: 08/30/2005 X
Initial Penalty:
Current Penalty:
Issuance Date: 07/28/2005
Nr Instances: 2
Nr Exposed: 2
Related Event Code (REC): A
Gravity: 03
Report ID: 0521100
Contest Date:
Final Order:
Emphasis:
| Type | Latest Event | Event Date | Penalty | Abatement Due Date | Citation Type | Failure to Abate Inspection |
|---|---|---|---|---|---|---|
| Penalty | I: Informal Settlement | 08/11/2005 | 08/30/2005 | Serious | ||
| Penalty | Z: Issued | 07/28/2005 | 08/30/2005 | Serious |
Text For Citation: 01 Item/Group: 001B Hazard: UNAPOPPROC
29 CFR 1910.147(c)(6)(i): The employer did not conduct an annual or more frequent inspection of the energy control procedure to ensure that the procedure and requirements of this standard were followed: a) Periodic inspection of the energy control procedures had not been conducted since 2000. b) Periodic inspection of the hydrostatic and pneumatic tank testing and inspection procedures had not been conducted. Abatement Certification and Abatement Documentation required.