Violation Detail
Standard Cited: 19100147 C04 II B The control of hazardous energy (lockout/tagout).
Inspection Nr: 281254.015
Citation: 01001A
Citation Type: Serious
Abatement Date: 3
Initial Penalty: $3,600.00
Current Penalty: $3,600.00
Issuance Date: 09/13/2012
Nr Instances: 1
Nr Exposed: 1
Related Event Code (REC):
Gravity: 5
Report ID: 0830500
Contest Date:
Final Order: 10/03/2012
Emphasis:
Type | Latest Event | Event Date | Penalty | Abatement Due Date | Citation Type | Failure to Abate Inspection |
---|---|---|---|---|---|---|
Penalty | I: Informal Settlement | 10/03/2012 | $3,600.00 | Serious | ||
Penalty | Z: Issued | 09/13/2012 | $3,600.00 | Serious |
Text For Citation: 01 Item/Group: 001A Hazard:
29 CFR 1910.147(c)(4)(ii)[B]: The energy control procedures did not clearly and specifically outline the steps for shutting down, isolating, blocking and securing machines or equipment to control hazardous energy. (a)Kelley Bean Company at 28810 County Road S., Brush, CO 80723: The employer did not ensure that the energy control procedures for the bean cleaning, washing and bagging equipment clearly and specifically outlined the steps for shutting down, isolating, blocking and securing machines or equipment to control hazardous energy. This condition exposed the employees to an uncontrolled energy source hazard.