Violation Detail
Standard Cited: 19260451 E01 General requirements.
Inspection Nr: 191439.015
Citation: 01004
Citation Type: Serious
Abatement Date: 05/17/2012 5
Initial Penalty: $4,200.00
Current Penalty: $250.00
Issuance Date: 04/26/2012
Nr Instances: 1
Nr Exposed: 1
Related Event Code (REC):
Gravity: 10
Report ID: 0524500
Contest Date: 05/29/2012
Final Order: 02/21/2013
Emphasis:
| Type | Latest Event | Event Date | Penalty | Abatement Due Date | Citation Type | Failure to Abate Inspection |
|---|---|---|---|---|---|---|
| Penalty | F: Formal Settlement | 02/21/2013 | $250.00 | 05/17/2012 | Serious | |
| Penalty | C: Contested | 05/29/2012 | $4,200.00 | 05/17/2012 | Serious | |
| Penalty | Z: Issued | 04/26/2012 | $4,200.00 | 05/17/2012 | Serious |
Text For Citation: 01 Item/Group: 004 Hazard:
29 CFR 1926.451(e)(1): When scaffold platforms were more than 2 feet (0.6 m) above or below a point of access, portable ladders, hook-on ladders, attachable ladders, stair towers (scaffold stairways/towers), stairway-type ladders (such as ladder stands), ramps, walkways, integral prefabricated scaffold access, or direct access from other scaffold, structure, personnel hoist, or similar surface was not used. Cross braces were used as a means of access: Employees conducting residential roofing activities were exposed to fall hazards of approximately 13.5 feet while working from a ladder jack scaffold. The center ladder that supported the ladder jack scaffold was used to access the working level.