Violation Detail
Standard Cited: 19100217 B09 V Mechanical power presses.
Inspection Nr: 189999.015
Citation: 01008
Citation Type: Serious
Abatement Date: 07/24/2012 2
Initial Penalty: $5,390.00
Current Penalty: $0.00
Issuance Date: 07/02/2012
Nr Instances: 27
Nr Exposed: 6
Related Event Code (REC):
Gravity: 10
Report ID: 0522000
Contest Date:
Final Order: 07/23/2012
Emphasis:
Type | Latest Event | Event Date | Penalty | Abatement Due Date | Citation Type | Failure to Abate Inspection |
---|---|---|---|---|---|---|
Penalty | I: Informal Settlement | 07/23/2012 | $0.00 | 07/24/2012 | Serious | |
Penalty | Z: Issued | 07/02/2012 | $5,390.00 | 07/24/2012 | Serious |
Text For Citation: 01 Item/Group: 008 Hazard:
29 CFR 1910.217(b)(9)(v): Air counterbalance cylinders shall incorporate means to prevent failure of capability (sudden loss of pressure) in event of air supply failure: (a) The Stamtec partial revolution presses (17), the Verson partial revolution presses (6), the Minster Partial Revolution Press (1), the Bliss Partial Revolution Press (1), the Danly Partial Revolution Press (1), and the Heller-Sutherland Partial Revolution Press (1), all had air counterbalances, but they had only one air pressure switch.