Violation Detail
Standard Cited: 19100253 B05 II I Oxygen-fuel gas welding and cutting.
Inspection Nr: 1720277.015
Citation: 01006B
Citation Type: Serious
Abatement Date: 07/25/2024 2
Initial Penalty: $0.00
Current Penalty: $0.00
Issuance Date: 06/26/2024
Nr Instances: 1
Nr Exposed: 3
Related Event Code (REC):
Gravity: 5
Report ID: 0830600
Contest Date:
Final Order: 07/23/2024
Emphasis:
| Type | Latest Event | Event Date | Penalty | Abatement Due Date | Citation Type | Failure to Abate Inspection |
|---|---|---|---|---|---|---|
| Penalty | I: Informal Settlement | 07/23/2024 | $0.00 | 07/25/2024 | Serious | |
| Penalty | Z: Issued | 06/26/2024 | $0.00 | 07/25/2024 | Serious |
Text For Citation: 01 Item/Group: 006B Hazard:
29 CFR 1910.253(b)(5)(ii)(I): Cylinders were not kept far enough away from the actual welding or cutting operation so that sparks, hot slag, or flame would not reach them: a) On or about January 09, 2024, and at times prior, acetylene and oxygen cylinders were stored in the welding area, less than 10 feet away from where welding activities were being performed and were not kept far enough away from actual welding so that sparks, hot slag or flame would not reach them exposing employees to fire hazards.