Violation Detail
Standard Cited: 19260652 A01 Requirements for protective systems.
Inspection Nr: 1720046.015
Citation: 01004
Citation Type: Serious
Abatement Date: 07/12/2024 2
Initial Penalty: $16,131.00
Current Penalty: $12,100.00
Issuance Date: 07/01/2024
Nr Instances: 1
Nr Exposed: 1
Related Event Code (REC): A
Gravity: 10
Report ID: 0214700
Contest Date:
Final Order: 08/19/2024
Emphasis:
Type | Latest Event | Event Date | Penalty | Abatement Due Date | Citation Type | Failure to Abate Inspection |
---|---|---|---|---|---|---|
Penalty | I: Informal Settlement | 08/19/2024 | $12,100.00 | 07/12/2024 | Serious | |
Penalty | Z: Issued | 07/01/2024 | $16,131.00 | 07/12/2024 | Serious |
Text For Citation: 01 Item/Group: 004 Hazard:
29 CFR 1926.652(a)(1):Each employee in an excavation was not protected from cave-ins by an adequate protective system designed in accordance with 29 CFR 1926.652 (b) or (c). a) Worksite, 1 Piper Lane, Head of Harbor, NY- Employee was working inside an approximately 40' long, 20' wide 18' deep excavation without protection from an adequate protective system exposing employees to a cave-in hazard; on or about 1/8/24. Note: Because abatement of this violation is already documented in the case file, the employer need not submit certification or documentation of abatement for this violation as normally required by CFR 1903.19.