Violation Detail
Standard Cited: 19100219 C02 I Mechanical power-transmission apparatus.
Inspection Nr: 1708588.015
Citation: 01005
Citation Type: Serious
Abatement Date: 05/21/2024
Initial Penalty: $10,163.00
Current Penalty: $10,163.00
Issuance Date: 05/02/2024
Nr Instances: 1
Nr Exposed: 12
Related Event Code (REC): A
Gravity: 10
Report ID: 0216000
Contest Date: 05/14/2024
Final Order:
Emphasis:
Type | Latest Event | Event Date | Penalty | Abatement Due Date | Citation Type | Failure to Abate Inspection |
---|---|---|---|---|---|---|
Penalty | C: Contested | 05/15/2024 | $10,163.00 | 05/21/2024 | Serious | |
Penalty | Z: Issued | 05/02/2024 | $10,163.00 | 05/21/2024 | Serious |
Text For Citation: 01 Item/Group: 005 Hazard:
29 CFR 1910.219(c)(2)(i):All exposed part(s) of horizontal shafting seven (7) feet or less from floor or working platform were not protected by stationary casing(s) enclosing shafting completely or by trough(s) enclosing sides and top or sides and bottom of shafting: On or about November 6th, 2023 Location: 1140 Grinnell Pl, Bronx, NY 10474 a) Employee #1 and #3 were exposed to an unguarded rotating shaft that drives the air-actuated vibrator levers of a volumetric concrete mixer truck. Shaft was located at 56 inches (4.7 feet) from the ground.