Violation Detail
Standard Cited: 19100146 J04 Permit-required confined spaces
Inspection Nr: 1689764.015
Citation: 01006C
Citation Type: Serious
Abatement Status: Abatement Completed
Initial Penalty: $0.00
Current Penalty: $0.00
Issuance Date: 11/09/2023
Nr Instances: 2
Nr Exposed: 1
Abatement Date: 05/08/2024
Gravity: 5
Report ID: 0215800
Contest Date: 12/04/2023
Final Order: 03/08/2024
Related Event Code (REC):
Emphasis:
Type | Latest Event | Event Date | Penalty | Abatement Due Date | Citation Type | Failure to Abate Inspection |
---|---|---|---|---|---|---|
Penalty | F: Formal Settlement | 03/08/2024 | $0.00 | 05/08/2024 | Serious | |
Penalty | C: Contested | 12/04/2023 | $0.00 | 12/29/2023 | Serious | |
Penalty | Z: Issued | 11/09/2023 | $0.00 | 12/29/2023 | Serious |
Text For Citation: 01 Item/Group: 006C Hazard:
29 CFR 1910.146(j)(4): The employer did not ensure that each entry supervisor verified that rescue services were available and that the means for summoning them were operable: a.) Building 5 Mid Phos Open Top Tank, Anoplate Corporation, 459 Pulaski Street, Syracuse NY, 13204, on or about 7/27/2023: An employee entered the mid phos open top tank in building 5, which was designated as a permit required confined space, to complete plastic welding repairs on the tank. The entry supervisor did not verify that rescue workers were available. b.) Tank 513, Anoplate Corporation, 400 Pulaski Street, Syracuse NY, 13204, on or about 8/2/2023: An employee entered Tank 513, which was designated as a permit required confined space, to complete plastic welding repairs on the tank. The entry supervisor did not verify that rescue workers were available. Abatement certification must be submitted for this item.