Violation Detail
Standard Cited: 19260451 B05 II General requirements.
Inspection Nr: 1674299.015
Citation: 01003
Citation Type: Serious
Abatement Date: 11/17/2023 2
Initial Penalty: $4,688.00
Current Penalty: $1,875.00
Issuance Date: 11/13/2023
Nr Instances: 1
Nr Exposed: 2
Related Event Code (REC): I
Gravity: 10
Report ID: 0214700
Contest Date: 11/30/2023
Final Order: 08/16/2024
Emphasis:
| Type | Latest Event | Event Date | Penalty | Abatement Due Date | Citation Type | Failure to Abate Inspection |
|---|---|---|---|---|---|---|
| Penalty | R: Review Commission | 08/16/2024 | $1,875.00 | 11/17/2023 | Serious | |
| Penalty | C: Contested | 11/30/2023 | $4,688.00 | 11/17/2023 | Serious | |
| Penalty | Z: Issued | 11/13/2023 | $4,688.00 | 11/17/2023 | Serious |
Text For Citation: 01 Item/Group: 003 Hazard:
29 CFR 1926.451(b)(5)(ii):The end of a platform greater than 10 feet in length extended over its support more than 18 inches and the platform was not designed and installed so that the cantilevered portion of the platform is able to support employees without tipping, or has guardrails which block employee access to the cantilevered end. a) Worksite: 8 Nyack Drive, East Northport, NY 11731 - The employee was performing electrical work while working from a pump jack scaffold. The scaffold platform extended approximately 4 feet past the support; on or about 6/1/2023 Note: The employer is required to submit abatement certification for this item in accordance with 29 CFR 1903.19.
Translate