Violation Detail
Standard Cited: 19100147 C07 I The control of hazardous energy (lockout/tagout).
Inspection Nr: 1639786.015
Citation: 01003C
Citation Type: Serious
Abatement Date: 03/13/2023 2
Initial Penalty: $0.00
Current Penalty: $0.00
Issuance Date: 02/22/2023
Nr Instances: 1
Nr Exposed: 3
Related Event Code (REC):
Gravity: 10
Report ID: 0418600
Contest Date:
Final Order: 03/27/2023
Emphasis:
Type | Latest Event | Event Date | Penalty | Abatement Due Date | Citation Type | Failure to Abate Inspection |
---|---|---|---|---|---|---|
Penalty | I: Informal Settlement | 03/27/2023 | $0.00 | 03/13/2023 | Serious | |
Penalty | Z: Issued | 02/22/2023 | $0.00 | 03/13/2023 | Serious |
Text For Citation: 01 Item/Group: 003C Hazard:
29 CFR 1910.147(c)(7)(i): The employer did not provide adequate training to ensure that the purpose and function of the energy control program was understood by employees: (a) Maintenance shop; on or about December 14, 2022, the employer exposed employees to crushed-by hazards in that employees were allowed to perform maintenance and servicing on equipment without being trained in lockout tag out.