Violation Detail
Standard Cited: 19100147 C01 The control of hazardous energy (lockout/tagout).
Inspection Nr: 1639786.015
Citation: 01003A
Citation Type: Serious
Abatement Date: 03/13/2023 2
Initial Penalty: $10,938.00
Current Penalty: $5,500.00
Issuance Date: 02/22/2023
Nr Instances: 1
Nr Exposed: 3
Related Event Code (REC):
Gravity: 10
Report ID: 0418600
Contest Date:
Final Order: 03/27/2023
Emphasis:
Type | Latest Event | Event Date | Penalty | Abatement Due Date | Citation Type | Failure to Abate Inspection |
---|---|---|---|---|---|---|
Penalty | I: Informal Settlement | 03/27/2023 | $5,500.00 | 03/13/2023 | Serious | |
Penalty | Z: Issued | 02/22/2023 | $10,938.00 | 03/13/2023 | Serious |
Text For Citation: 01 Item/Group: 003A Hazard:
29 CFR 1910.147(c)(1):The employer did not establish a program consisting of an energy control procedure, employee training and periodic inspections to ensure that before any employee performed any servicing or maintenance on a machine or equipment where the unexpected energizing, startup or release of stored energy could occur and cause injury, the machine or equipment shall be isolated from the energy source and rendered inoperative: (a) Maintenance shop; on or about December 14, 2022, the employer exposed employees to crushed-by hazards in that employees were allowed to perform maintenance and servicing on equipment without having a lockout program, without being trained in lockout tag out, and without machine specific lockout tag out procedures.