Violation Detail
Standard Cited: 19100119 J04 I Process safety management of highly hazardous chemicals.
Inspection Nr: 1633318.015
Citation: 01006
Citation Type: Serious
Abatement Date: 10/01/2024 2
Initial Penalty: $15,625.00
Current Penalty: $11,000.00
Issuance Date: 05/08/2023
Nr Instances: 1
Nr Exposed: 20
Related Event Code (REC):
Gravity: 10
Report ID: 0213600
Contest Date:
Final Order: 07/26/2023
Emphasis:
Type | Latest Event | Event Date | Penalty | Abatement Due Date | Citation Type | Failure to Abate Inspection |
---|---|---|---|---|---|---|
Penalty | P: Petition to Mod Abatement | 03/14/2024 | $11,000.00 | 10/01/2024 | Serious | |
Penalty | I: Informal Settlement | 07/26/2023 | $11,000.00 | 04/08/2024 | Serious | |
Penalty | Z: Issued | 05/08/2023 | $15,625.00 | 06/08/2023 | Serious |
Text For Citation: 01 Item/Group: 006 Hazard:
29 CFR 1910.119(j)(4)(i): The employer did not perform inspection and tests on process equipment (a) Room 30 HEPES process - On or about 11/9/2022, the employer operates and maintains a covered process involving methanol, a class 1 flammable liquid having a flashpoint below 100F exceeding the TQ of 10,000 lbs. The employer did not perform inspection and tests on process equipment including the crystallizer. (b) Room 30 HEPES process - On or about 11/9/2022, the employer operates and maintains a covered process involving methanol, a class 1 flammable liquid having a flashpoint below 100F exceeding the TQ of 10,000 lbs. The employer did not perform inspection and tests on process equipment including the crystallizer high-level shut-off. (c) Room 30 HEPES process - On or about 11/9/2022, the employer operates and maintains a covered process involving methanol, a class 1 flammable liquid having a flashpoint below 100F exceeding the TQ of 10,000 lbs. The employer did not perform inspection and tests on process equipment including the crystallizer (AMETEK DR 3500 RADAR) level transmitter. (d) Room 30 HEPES process - On or about 11/9/2022, the employer operates and maintains a covered process involving methanol, a class 1 flammable liquid having a flashpoint below 100F exceeding the TQ of 10,000 lbs. The employer did not perform inspection and tests on process equipment including the stainless steel pipe associated with the crystallizer. (e) Room 30 HEPES process - On or about 11/9/2022, the employer operates and maintains a covered process involving methanol, a class 1 flammable liquid having a flashpoint below 100F exceeding the TQ of 10,000 lbs. The employer did not perform inspection and tests on process equipment including the BREDEL-50 hose pump. (f) Room 30 HEPES process- On or about 11/9/2022, the employer operates and maintains a covered process involving methanol, a class 1 flammable liquid having a flashpoint below 100F exceeding the TQ of 10,000 lbs. The employer did not perform inspection and tests on process equipment, including the crystallizer vent line filter. (g) Room 30 HEPES process- On or about 11/9/2022, the employer operates and maintains a covered process involving methanol, a class 1 flammable liquid having a flashpoint below 100F exceeding the TQ of 10,000 lbs. The employer did not perform inspection and tests on process equipment, including electrical grounding of the process equipment. ABATEMENT DOCUMENTATION REQUIRED