Violation Detail
Standard Cited: 19100023 D02 Ladders.
Inspection Nr: 1601732.015
Citation: 01001A
Citation Type: Other
Abatement Date: 10/28/2022 2
Initial Penalty: $8,806.00
Current Penalty: $6,525.73
Issuance Date: 09/12/2022
Nr Instances: 2
Nr Exposed: 6
Related Event Code (REC): C
Gravity: 5
Report ID: 0112000
Contest Date: 10/11/2022
Final Order: 09/25/2023
Emphasis:
Type | Latest Event | Event Date | Penalty | Abatement Due Date | Citation Type | Failure to Abate Inspection |
---|---|---|---|---|---|---|
Penalty | F: Formal Settlement | 09/25/2023 | $6,525.73 | 10/28/2022 | Other | |
Penalty | C: Contested | 10/11/2022 | $8,806.00 | 10/28/2022 | Serious | |
Penalty | Z: Issued | 09/12/2022 | $8,806.00 | 10/28/2022 | Serious |
Text For Citation: 01 Item/Group: 001A Hazard:
29 CFR 1910.23(d)(2): The employer did not ensure that the minimum perpendicular distance from the centerline of the steps or rungs, or grab bars, or both, to the nearest permanent object in back of the ladder is 7 inches (18 cm): In the following locations, sufficient clearance was not provided behind fixed ladders: A. Community Building, Near Cooling Tower: On, or about, June 16, 2022, the clearance from the centerline of the rungs on the fixed ladder was measured to be six inches from the building surface. B. Fleet Building: On, or about, July 13, 2022, the clearance from the 22nd rung (ascending) was measured to be four inches from the roof edge.