Violation Detail
Standard Cited: 19100147 C07 I B The control of hazardous energy (lockout/tagout).
Inspection Nr: 1589272.015
Citation: 01003A
Citation Type: Serious
Abatement Date: 10/07/2022 2
Initial Penalty: $5,801.00
Current Penalty: $6,000.00
Issuance Date: 09/13/2022
Nr Instances: 1
Nr Exposed: 1
Related Event Code (REC): R
Gravity: 5
Report ID: 0336000
Contest Date:
Final Order: 09/30/2022
Emphasis:
| Type | Latest Event | Event Date | Penalty | Abatement Due Date | Citation Type | Failure to Abate Inspection |
|---|---|---|---|---|---|---|
| Penalty | I: Informal Settlement | 09/30/2022 | $6,000.00 | 10/07/2022 | Serious | |
| Penalty | Z: Issued | 09/13/2022 | $5,801.00 | 10/07/2022 | Serious |
Text For Citation: 01 Item/Group: 003A Hazard:
29 CFR 1910.147(c)(7)(i)(B):Each affected employee was not instructed in the purpose and use of the energy control procedure: a.) American Cap Company LLC; Production area- on or about 4/6/22, and times prior thereto, the employer did not ensure that affected employees who operate the equipment including, but not limited to the Toyokoki hyb12530 press brake received affected employee lockout tagout training. ABATEMENT CERTIFICATION REQUIRED: Abatement certification is required within 10 days after the abatement date noted on the citation (see below). This certification shall include a statement that abatement is complete, the date abatement was completed, method of abatement, and state that employees and their representatives were informed of this abatement.