Violation Detail
Standard Cited: 19100147 C06 II The control of hazardous energy (lockout/tagout).
Inspection Nr: 1588430.015
Citation: 02001
Citation Type: Other
Abatement Date: 09/16/2022 2
Initial Penalty: $0.00
Current Penalty: $15,625.00
Issuance Date: 09/09/2022
Nr Instances: 2
Nr Exposed: 20
Related Event Code (REC): C
Gravity:
Report ID: 0524200
Contest Date: 10/03/2022
Final Order: 08/16/2023
Emphasis:
Type | Latest Event | Event Date | Penalty | Abatement Due Date | Citation Type | Failure to Abate Inspection |
---|---|---|---|---|---|---|
Penalty | F: Formal Settlement | 08/16/2023 | $15,625.00 | 09/16/2022 | Other | |
Penalty | C: Contested | 10/05/2022 | $0.00 | 09/28/2022 | Other | |
Penalty | Z: Issued | 09/09/2022 | $0.00 | 09/28/2022 | Other |
Text For Citation: 02 Item/Group: 001 Hazard:
29 CFR 1910.147(c)(6)(ii): The employer did not certify that the periodic inspections have been performed: (a) Mogul 6 ? On or about March 15, 2022, the employer failed to certify the date a periodic inspection had been performed for the Mogul 6 Depositor. (b) Mogul 5 ? On or about March 19, 2022, failed to certify the date a periodic inspection had been performed for the Mogul 5 Stacker.