Violation Detail
Standard Cited: 19100147 C04 II B The control of hazardous energy (lockout/tagout).
Inspection Nr: 1584871.015
Citation: 01001A
Citation Type: Serious
Abatement Date: 09/26/2022 2
Initial Penalty: $10,151.00
Current Penalty: $9,500.00
Issuance Date: 09/09/2022
Nr Instances: 1
Nr Exposed: 4
Related Event Code (REC): A
Gravity: 10
Report ID: 0625700
Contest Date:
Final Order: 10/06/2022
Emphasis:
Type | Latest Event | Event Date | Penalty | Abatement Due Date | Citation Type | Failure to Abate Inspection |
---|---|---|---|---|---|---|
Penalty | I: Informal Settlement | 10/06/2022 | $9,500.00 | 09/26/2022 | Serious | |
Penalty | Z: Issued | 09/09/2022 | $10,151.00 | 09/26/2022 | Serious |
Text For Citation: 01 Item/Group: 001A Hazard:
29 CFR 1910.147(c)(4)(ii)(B): The energy control procedures did not clearly and specifically outline the steps for shutting down, isolating, blocking and securing machines or equipment to control hazardous energy. On or about 03/17/2022, in the formulation department, the employer did not ensure that specific lockout/tagout procedures were implemented for an AFMG-56 MKIII Automatic Feed Mixer (Meat) Grinder.