Violation Detail
Standard Cited: 19100219 I02 Mechanical power-transmission apparatus.
Inspection Nr: 1578898.015
Citation: 01003B
Citation Type: Serious
Abatement Date: 11/22/2022 2
Initial Penalty: $0.00
Current Penalty: $0.00
Issuance Date: 07/27/2022
Nr Instances: 1
Nr Exposed: 3
Related Event Code (REC): R
Gravity: 5
Report ID: 0336000
Contest Date:
Final Order: 08/09/2022
Emphasis:
| Type | Latest Event | Event Date | Penalty | Abatement Due Date | Citation Type | Failure to Abate Inspection |
|---|---|---|---|---|---|---|
| Penalty | I: Informal Settlement | 08/09/2022 | $0.00 | 11/22/2022 | Serious | |
| Penalty | Z: Issued | 07/27/2022 | $0.00 | 08/22/2022 | Serious |
Text For Citation: 01 Item/Group: 003B Hazard:
29 CFR 1910.219(i)(2): Shaft coupling(s) extended beyond the flange of the coupling and were not covered with safety sleeve(s): A) Montgomery Truss & Panel, Inc. on or about February 17, 2022 at the address of 7 East gate Industrial Park Drive, Grove City, PA: Employees were exposed to unguarded shaft couplings 4.5 feet above the ground on the outfeed side of the wall panel saw.