Violation Detail
Standard Cited: 19100219 E01 I Mechanical power-transmission apparatus.
Inspection Nr: 1577619.015
Citation: 01004B
Citation Type: Serious
Abatement Date: 07/01/2022 2
Initial Penalty: $11,396.00
Current Penalty: $0.00
Issuance Date: 06/14/2022
Nr Instances: 1
Nr Exposed: 15
Related Event Code (REC): C
Gravity: 5
Report ID: 0522500
Contest Date:
Final Order: 07/08/2022
Emphasis:
Type | Latest Event | Event Date | Penalty | Abatement Due Date | Citation Type | Failure to Abate Inspection |
---|---|---|---|---|---|---|
Penalty | I: Informal Settlement | 07/08/2022 | $0.00 | 07/01/2022 | Serious | |
Penalty | Z: Issued | 06/14/2022 | $11,396.00 | 07/01/2022 | Serious |
Text For Citation: 01 Item/Group: 004B Hazard:
29 CFR 1910.219(e)(1)(i): Where both runs of horizontal belts are seven (7) feet or less from the floor level, the guard shall extend to at least fifteen (15) inches above the belt or to a standard height, except that where both runs of a horizontal belt are 42 inches or less from the floor, the belt shall be fully enclosed in accordance with paragraphs (m) and (o) of this section. a. On or before February 8, 2022, the employer failed to ensure employees were protected from the rotating belts of the feeding assembly of Lid Printer #7. The four belts of the feeding assembly were not guarded, thereby exposing employees to a caught-in hazard.