Violation Detail
Standard Cited: 19100219 D01 Mechanical power-transmission apparatus.
Inspection Nr: 1574235.015
Citation: 01003A
Citation Type: Serious
Abatement Date: 08/09/2022 2
Initial Penalty: $3,419.00
Current Penalty: $2,051.40
Issuance Date: 07/21/2022
Nr Instances: 1
Nr Exposed: 1
Related Event Code (REC):
Gravity: 5
Report ID: 0215800
Contest Date:
Final Order: 10/10/2022
Emphasis:
Type | Latest Event | Event Date | Penalty | Abatement Due Date | Citation Type | Failure to Abate Inspection |
---|---|---|---|---|---|---|
Penalty | I: Informal Settlement | 10/10/2022 | $2,051.40 | 08/09/2022 | Serious | |
Penalty | Z: Issued | 07/21/2022 | $3,419.00 | 08/09/2022 | Serious |
Text For Citation: 01 Item/Group: 003A Hazard:
29 CFR 1910.219(d)(1):Pulley(s) with part(s) seven feet or less from the floor or work platform were not guarded in accordance with the requirements specified in 29 CFR 1910.219(m) Standard guards-general requirements and (o) Approved materials: (a) In the saw mill facility, on or about 3/24/2022: The main saw head and edger were driven by 10, 7/8" thick semi-V belts over a pullies on a transmission shaft that was powered by a diesel engine. The 13.5" pullies on the transmission shaft are 38" off the ground and unguarded.