Violation Detail
Standard Cited: 19260451 C01 General requirements.
Inspection Nr: 1573280.015
Citation: 01001
Citation Type: Serious
Abatement Date: 03/07/2022 5
Initial Penalty: $4,102.00
Current Penalty: $4,102.00
Issuance Date: 02/04/2022
Nr Instances: 2
Nr Exposed: 3
Related Event Code (REC):
Gravity: 5
Report ID: 0636900
Contest Date:
Final Order: 03/07/2022
Emphasis:
Type | Latest Event | Event Date | Penalty | Abatement Due Date | Citation Type | Failure to Abate Inspection |
---|---|---|---|---|---|---|
Penalty | Z: Issued | 02/04/2022 | $4,102.00 | 03/07/2022 | Serious |
Text For Citation: 01 Item/Group: 001 Hazard:
29 CFR 1926.451(c)(1):Supported scaffolds with a height to base width (including outrigger supports, if used) ratio of more than four to one (4:1) were not restrained from tipping by guying, tying, bracing, or equivalent means, as set forth in subparagraphs (i) - (iii) of this paragraph. a. On or about January 19, 2022, and at times prior thereto, at residential construction, employees performed masonry activities on three (3) tiers high scaffold system(s) that was not restrained, exposing the employees to fall hazards over 12 feet. b. On or about January 19, 2022, and at times prior thereto, at residential construction, employees performed masonry activities on three (3) tiers high scaffold system(s) that was not adequate firmed to the foundation.