Powered by GoogleTranslate

Violation Detail

Standard Cited: 19100332 B01 Training

Inspection Nr: 1571369.015

Citation: 01007A

Citation Type: Serious

Abatement Status: Abatement Completed

Initial Penalty: $10,256.00

Current Penalty: $5,000.00

Issuance Date: 05/16/2022

Nr Instances: 1

Nr Exposed: 1

Abatement Date: 07/05/2022

Gravity: 5

Report ID: 0112000

Contest Date:

Final Order: 06/08/2022

Related Event Code (REC):

Emphasis:


Penalty and Failure to Abate Event History
Type Latest Event Event Date Penalty Abatement Due Date Citation Type Failure to Abate Inspection
Penalty I: Informal Settlement 06/08/2022 $5,000.00 07/05/2022 Serious  
Penalty Z: Issued 05/16/2022 $10,256.00 07/05/2022 Serious  

Text For Citation: 01 Item/Group: 007A Hazard:

29 CFR 1910.332(b)(1): Employees were not trained in and familiar with the safety-related work practices required by 1910.331 through 1910.335 that pertained to their respective job assignments: Company: Maintenance personnel had not been trained regarding what work practices and protective equipment was required to protect them against electric shock, arc flash and arc blast hazards while performing live electrical work such as live trouble-shooting and verifying whether or not electrical equipment was properly de-energized.

Thank You for Visiting Our Website

You are exiting the Department of Labor's Web server.

The Department of Labor does not endorse, takes no responsibility for, and exercises no control over the linked organization or its views, or contents, nor does it vouch for the accuracy or accessibility of the information contained on the destination server. The Department of Labor also cannot authorize the use of copyrighted materials contained in linked Web sites. Users must request such authorization from the sponsor of the linked Web site. Thank you for visiting our site. Please click the button below to continue.