Violation Detail
Standard Cited: 19260501 B04 I Duty to have fall protection.
Inspection Nr: 1568739.015
Citation: 01002
Citation Type: Serious
Abatement Date: 3
Initial Penalty: $14,502.00
Current Penalty: $11,601.60
Issuance Date: 05/31/2022
Nr Instances: 1
Nr Exposed: 3
Related Event Code (REC):
Gravity: 10
Report ID: 0420600
Contest Date:
Final Order: 06/27/2022
Emphasis:
| Type | Latest Event | Event Date | Penalty | Abatement Due Date | Citation Type | Failure to Abate Inspection |
|---|---|---|---|---|---|---|
| Penalty | I: Informal Settlement | 06/27/2022 | $11,601.60 | Serious | ||
| Penalty | Z: Issued | 05/31/2022 | $14,502.00 | Serious |
Text For Citation: 01 Item/Group: 002 Hazard:
29 CFR 1926.501(b)(4)(i): Each employee on walking/working surfaces was not protected from falling through holes (including skylights) more than 6 feet (1.8 m) above lower levels, by personal fall arrest systems, covers, or guardrail systems erected around such holes: a. 18820 Cortez Blvd., Brooksville, Florida, On or about December 13, 2021, employees were exposed to fall hazards of more than 20-feet while installing a new Thermoplastic Polyolefin (TPO) roof covering system over the existing Purlin Bearing Rib (PBR) metal panels and skylight type corrugated fiberglass panels. The roof had a 1:12 pitch; 20-feet to the eave and 25-feet to the center top. Fall protection equipment was not installed or utilized nor were covers placed over the fiberglass panels to prevent employees from falling.