Violation Detail
Standard Cited: 19100147 D The control of hazardous energy (lockout/tagout).
Inspection Nr: 1567585.015
Citation: 01002
Citation Type: Serious
Abatement Status: Abatement Completed
Initial Penalty: $14,502.00
Current Penalty: $14,502.00
Issuance Date: 02/02/2022
Nr Instances: 1
Nr Exposed: 6
Abatement Date: 03/09/2022
Gravity: 10
Report ID: 0522500
Contest Date: 02/23/2022
Final Order: 08/19/2022
Related Event Code (REC): R
Emphasis:
| Type | Latest Event | Event Date | Penalty | Abatement Due Date | Citation Type | Failure to Abate Inspection |
|---|---|---|---|---|---|---|
| Penalty | J: ALJ Decision | 08/19/2022 | $14,502.00 | 03/09/2022 | Serious | |
| Penalty | C: Contested | 02/24/2022 | $14,502.00 | 03/09/2022 | Serious | |
| Penalty | Z: Issued | 02/02/2022 | $14,502.00 | 03/09/2022 | Serious |
Text For Citation: 01 Item/Group: 002 Hazard:
29 CFR 1910.147(d):Application of control. The established procedures for the application of energy control (the lockout or tagout procedures) was not done in sequence as required by 29 CFR 1910.147(d)(1) through (d)(6): a. New AVD: 29 CFR 1910.212(a)(1):One or more methods of machine guarding was not provided to protect the operator and other employees in the machine area from hazards such as those created by point of operation, ingoing nip points, rotating parts, flying chips and sparks: On or about November 17, 2021, the employer did not ensure that an employee was protected from crushing, amputation, and burn injuries. An ingoing nip point on the Lam 12 laminator machine was left unguarded while an employee was cleaning a roller on the ingoing side