Violation Detail
Standard Cited: 19100147 C04 II B The control of hazardous energy (lockout/tagout).
Inspection Nr: 1562977.015
Citation: 02001
Citation Type: Other
Abatement Date: 03/09/2022 2
Initial Penalty: $0.00
Current Penalty: $0.00
Issuance Date: 01/28/2022
Nr Instances: 1
Nr Exposed: 33
Related Event Code (REC):
Gravity:
Report ID: 0524700
Contest Date:
Final Order: 03/02/2022
Emphasis:
| Type | Latest Event | Event Date | Penalty | Abatement Due Date | Citation Type | Failure to Abate Inspection |
|---|---|---|---|---|---|---|
| Penalty | I: Informal Settlement | 03/02/2022 | $0.00 | 03/09/2022 | Other | |
| Penalty | Z: Issued | 01/28/2022 | $0.00 | 02/15/2022 | Other |
Text For Citation: 02 Item/Group: 001 Hazard:
29 CFR 1910.147(c)(4)(ii)(B):The energy control procedures did not clearly and specifically outline the steps for shutting down, isolating, blocking and securing machines or equipment to control hazardous energy. Mansfield Engineered Components, Inc. - Mansfield, Ohio: On or about November 1, 2021, the employer did not ensure energy control procedures for the #R-28 Milford Rivet & Machine Co. riveter (model S413; s/n 1342) identified specific steps to follow to render safe the residual energy of the flywheel. Employees that unjam the machine were exposed to rotating part and nip-point hazards. In accordance with 29 CFR 1903.19(d), abatement certification is required for this violation (using the CERTIFICATION OF CORRECTIVE ACTION WORKSHEET).
Translate