Violation Detail
Standard Cited: 19100147 C04 I The control of hazardous energy (lockout/tagout).
Inspection Nr: 1561048.015
Citation: 01001A
Citation Type: Other
Abatement Date: 04/26/2022 2
Initial Penalty: $12,431.00
Current Penalty: $9,000.00
Issuance Date: 03/31/2022
Nr Instances: 1
Nr Exposed: 4
Related Event Code (REC):
Gravity: 5
Report ID: 0317500
Contest Date:
Final Order: 04/22/2022
Emphasis:
| Type | Latest Event | Event Date | Penalty | Abatement Due Date | Citation Type | Failure to Abate Inspection |
|---|---|---|---|---|---|---|
| Penalty | I: Informal Settlement | 04/22/2022 | $9,000.00 | 04/26/2022 | Other | |
| Penalty | Z: Issued | 03/31/2022 | $12,431.00 | 04/26/2022 | Serious |
Text For Citation: 01 Item/Group: 001A Hazard:
29 CFR 1910.147(c)(4)(i): Procedures were not developed, documented and utilized for the control of potentially hazardous energy when employees were engaged in the activities covered by this section: Instances including, but not limited to, the following: a) Job site, 111 Marvista Street, Pittsburgh, PA: On or about October 25, 2021, the employer did not ensure that machine specific energy control procedures were documented and utilized for work such as jam clearing activities on Folder 3, unit number 5051076/98. b) Job site, 111 Marvista Street, Pittsburgh, PA: On or about October 25, 2021, the employer did not ensure that machine specific energy control procedures were documented and utilized for work such as machinery troubleshooting/adjustments/repairs on Folder 3, unit number 5051076/98.
Translate