Violation Detail
Standard Cited: 19100219 D01 Mechanical power-transmission apparatus.
Inspection Nr: 1516082.015
Citation: 01003A
Citation Type: Serious
Abatement Date: 08/17/2021 2
Initial Penalty: $5,461.00
Current Penalty: $3,003.55
Issuance Date: 07/22/2021
Nr Instances: 1
Nr Exposed: 3
Related Event Code (REC):
Gravity: 5
Report ID: 0728500
Contest Date:
Final Order: 08/05/2021
Emphasis:
| Type | Latest Event | Event Date | Penalty | Abatement Due Date | Citation Type | Failure to Abate Inspection |
|---|---|---|---|---|---|---|
| Penalty | I: Informal Settlement | 08/05/2021 | $3,003.55 | 08/17/2021 | Serious | |
| Penalty | Z: Issued | 07/22/2021 | $5,461.00 | 08/17/2021 | Serious |
Text For Citation: 01 Item/Group: 003A Hazard:
29 CFR 1910.219(d)(1):Pulley(s) with part(s) seven feet or less from the floor or work platform were not guarded in accordance with the requirements specified in 29 CFR 1910.219(m) and (o): At a worksite located at 1401 W. Junge Boulevard, Joplin, MO employees were exposed to amputation hazards in the bin room. The pulleys were not fully guarded for the Duroflow Blower that powers the # 1, # 2 and # 3 bins. The belts and pulleys create ingoing nippoints.
Translate