Violation Detail
Standard Cited: 19100147 F03 II D The control of hazardous energy (lockout/tagout).
Inspection Nr: 1514967.015
Citation: 01001
Citation Type: Serious
Abatement Date: 06/07/2021 2
Initial Penalty: $7,510.00
Current Penalty: $5,257.00
Issuance Date: 05/07/2021
Nr Instances: 1
Nr Exposed: 2
Related Event Code (REC):
Gravity: 5
Report ID: 0521100
Contest Date:
Final Order: 08/06/2021
Emphasis:
| Type | Latest Event | Event Date | Penalty | Abatement Due Date | Citation Type | Failure to Abate Inspection |
|---|---|---|---|---|---|---|
| Penalty | I: Informal Settlement | 08/06/2021 | $5,257.00 | 06/07/2021 | Serious | |
| Penalty | Z: Issued | 05/07/2021 | $7,510.00 | 06/07/2021 | Serious |
Text For Citation: 01 Item/Group: 001 Hazard:
29 CFR 1910.147(f)(3)(ii)(D): Each authorized employee shall affix a personal lockout or tagout device to the group lockout device, group lockbox, or comparable mechanism when he or she begins work, and shall remove those devices when he or she stops working on the machine or equipment being serviced or maintained: At a facility located at 7005 Rickyval Street, Weston, WI 54476; when two employees were conducting cleaning in and around the Mereen-Johnson gang rip saw (Model #435H, S# MJ2773), the employer did not ensure each authorized employee affixed a personal lockout device to a group lockout device, group lockbox or compatible mechanism when they were potentially exposed to caught-between and amputation hazards from unexpected energization of the electrical and pneumatic components of the saw.
Translate