Violation Detail
Standard Cited: 19100147 D02 The control of hazardous energy (lockout/tagout).
Inspection Nr: 1511714.015
Citation: 01001C
Citation Type: Serious
Abatement Date: 08/16/2021 2
Initial Penalty: $0.00
Current Penalty: $0.00
Issuance Date: 07/13/2021
Nr Instances: 1
Nr Exposed: 1
Related Event Code (REC): A;R
Gravity: 10
Report ID: 0522500
Contest Date:
Final Order: 08/10/2021
Emphasis:
| Type | Latest Event | Event Date | Penalty | Abatement Due Date | Citation Type | Failure to Abate Inspection |
|---|---|---|---|---|---|---|
| Penalty | Z: Issued | 07/13/2021 | $0.00 | 08/16/2021 | Serious |
Text For Citation: 01 Item/Group: 001C Hazard:
29 CFR 1910.147(d)(2):Machine or equipment shutdown. The machine or equipment shall be turned off or shut down using the procedures established for the machine or equipment. An orderly shutdown must be utilized to avoid any additional or increased hazard(s) to employees as a result of the equipment stoppage. a. On or about and prior to January 22, 2021, machine operators did not turn off or shutdown the Forstner machine prior to performing activities covered by this part. A machine operator was clearing air bubbles from film applied to metal material related to Forstner machine without having performed an orderly shutdown as part of procedures established for this task. The task of removing the bubbles from the film exposed employees to being caught in the mechanical material feed mechanism for the point of operation for the machine. On this date, an employee performing this task was injured and suffered severe lacerations to the right hand.