Violation Detail
Standard Cited: 19100147 C06 I The control of hazardous energy (lockout/tagout).
Inspection Nr: 1508836.015
Citation: 02001
Citation Type: Other
Abatement Date: 06/28/2021 2
Initial Penalty: $0.00
Current Penalty: $0.00
Issuance Date: 05/24/2021
Nr Instances: 1
Nr Exposed: 5
Related Event Code (REC): R
Gravity:
Report ID: 0316700
Contest Date:
Final Order: 06/22/2021
Emphasis:
| Type | Latest Event | Event Date | Penalty | Abatement Due Date | Citation Type | Failure to Abate Inspection |
|---|---|---|---|---|---|---|
| Penalty | Z: Issued | 05/24/2021 | $0.00 | 06/28/2021 | Other |
Text For Citation: 02 Item/Group: 001 Hazard:
29 CFR 1910.147(c)(6)(i):The employer did not conduct a periodic inspection of the energy control procedure at least annually to ensure that the procedure and the requirement of this standard were being followed: a) Mt. Airy Lumber Company, LLC - The employer conducted an annual review of the Lockout/Tagout Program; however, the annual periodic inspection of the lockout procedures to ensure compliance was not implemented, on or about May 4, 2021. Abatement certification required within 10 days after abatement date. The certification shall include a statement that abatement is complete, date and method of abatement, and states employees and their representatives were informed of this abatement.
Translate