Violation Detail
Standard Cited: 19260651 I02 Specific Excavation Requirements.
Inspection Nr: 1507413.015
Citation: 01001
Citation Type: Serious
Abatement Date: 06/14/2021 7
Initial Penalty: $5,461.00
Current Penalty: $5,461.00
Issuance Date: 06/02/2021
Nr Instances: 1
Nr Exposed: 2
Related Event Code (REC):
Gravity: 10
Report ID: 0524200
Contest Date:
Final Order: 06/30/2021
Emphasis:
| Type | Latest Event | Event Date | Penalty | Abatement Due Date | Citation Type | Failure to Abate Inspection |
|---|---|---|---|---|---|---|
| Penalty | Z: Issued | 06/02/2021 | $5,461.00 | 06/14/2021 | Serious |
Text For Citation: 01 Item/Group: 001 Hazard:
29 CFR 1926.651(i)(2): Excavation below the level of the base or footing of any foundation or retaining wall that could be reasonably expected to pose a hazard to the employees was not prohibited: a) On December 18, 2020, employees were exposed to cave-in and struck-by hazards where the area below footings and foundation walls were excavated and no support system was provided. In accordance with 29 CFR 1903.19(d), abatement certification is required for this violation (using the CERTIFICATION OF CORRECTIVE ACTION WORKSHEET), and in addition, documentation demonstrating that abatement is complete must be included with your certification. This documentation may include, but is not limited to, evidence of the purchase or repair of the equipment, photographic or video evidence of abatement, or other written records.
Translate