Violation Detail
Standard Cited: 19100147 C06 I The control of hazardous energy (lockout/tagout).
Inspection Nr: 1506394.015
Citation: 01001A
Citation Type: Serious
Abatement Date: 04/26/2021 2
Initial Penalty: $13,653.00
Current Penalty: $13,653.00
Issuance Date: 03/31/2021
Nr Instances: 1
Nr Exposed: 1
Related Event Code (REC):
Gravity: 10
Report ID: 0521700
Contest Date:
Final Order: 04/28/2021
Emphasis:
| Type | Latest Event | Event Date | Penalty | Abatement Due Date | Citation Type | Failure to Abate Inspection |
|---|---|---|---|---|---|---|
| Penalty | I: Informal Settlement | 04/28/2021 | $13,653.00 | 04/26/2021 | Serious | |
| Penalty | Z: Issued | 03/31/2021 | $13,653.00 | 04/26/2021 | Serious |
Text For Citation: 01 Item/Group: 001A Hazard:
29 CFR 1910.147(c)(6)(i): The employer did not conduct a periodic inspection of the energy control procedure at least annually to ensure that the procedure and the requirement of this standard were being followed: a.) Production Floor - On or about December 7, 2020, an authorized employee performed a service and/or maintenance task on the MTech Ladder Wire Machine, Model 00, Serial No. 8. The employer did not ensure a periodic inspection of the energy control procedure was performed at least annually as required by the standard.
Translate