Violation Detail
Standard Cited: 19100217 C02 I A Mechanical power presses.
Inspection Nr: 1500262.015
Citation: 01001
Citation Type: Other
Abatement Date: 02/25/2021 2
Initial Penalty: $12,288.00
Current Penalty: $2,000.00
Issuance Date: 01/29/2021
Nr Instances: 2
Nr Exposed: 4
Related Event Code (REC): R
Gravity: 10
Report ID: 0522000
Contest Date:
Final Order: 02/10/2021
Emphasis:
| Type | Latest Event | Event Date | Penalty | Abatement Due Date | Citation Type | Failure to Abate Inspection |
|---|---|---|---|---|---|---|
| Penalty | I: Informal Settlement | 02/10/2021 | $2,000.00 | 02/25/2021 | Other | |
| Penalty | Z: Issued | 01/29/2021 | $12,288.00 | 02/25/2021 | Serious |
Text For Citation: 01 Item/Group: 001 Hazard:
29 CFR 1910.217(c)(2)(i)(a): Safeguarding the point of operation - Point of operation guards. Every point of operation guard shall meet the following design, construction, application, and adjustment requirements:: It shall prevent entry of hands or fingers into the point of operation by reaching through, over, under or around the guard; a) On and after October 28, 2020 the point of operation guard on the Opt 10 nut welder (SN: 23A342) was not guarded to prevent entry of hands into the point of operation.