Violation Detail
Standard Cited: 19100147 D03 The control of hazardous energy (lockout/tagout).
Inspection Nr: 1497471.015
Citation: 01001
Citation Type: Serious
Abatement Date: 12/02/2020 2
Initial Penalty: $8,096.00
Current Penalty: $8,096.00
Issuance Date: 11/12/2020
Nr Instances: 1
Nr Exposed: 3
Related Event Code (REC): R
Gravity: 5
Report ID: 0317500
Contest Date:
Final Order: 12/03/2020
Emphasis:
| Type | Latest Event | Event Date | Penalty | Abatement Due Date | Citation Type | Failure to Abate Inspection |
|---|---|---|---|---|---|---|
| Penalty | I: Informal Settlement | 12/03/2020 | $8,096.00 | 12/02/2020 | Serious | |
| Penalty | Z: Issued | 11/12/2020 | $8,096.00 | 12/02/2020 | Serious |
Text For Citation: 01 Item/Group: 001 Hazard:
29 CFR 1910.147(d)(3): All energy isolating devices that were needed to control the energy to the machine or equipment were not physically located and operated in such a manner as to isolate the machine or equipment from the energy source(s): (a) Hazemag Impactor, 6th & Center Streets, Tarentum, PA- On or about October 13, 2020, employees performing maintenance and repairs on the Hazemag Impactor did not isolate all energy sources such as but not limited the energy source of gravity for the access door.