Violation Detail
Standard Cited: 19100147 D03 The control of hazardous energy (lockout/tagout).
This violation item has been deleted.
Inspection Nr: 1493063.015
Citation: 01001B
Citation Type: Serious
Abatement Date: 12/02/2020 6
Initial Penalty: $0.00
Current Penalty: $0.00
Issuance Date: 10/14/2020
Nr Instances: 1
Nr Exposed: 1
Related Event Code (REC):
Gravity: 5
Report ID: 0729300
Contest Date: 11/03/2020
Final Order: 10/28/2021
Emphasis:
| Type | Latest Event | Event Date | Penalty | Abatement Due Date | Citation Type | Failure to Abate Inspection |
|---|---|---|---|---|---|---|
| Penalty | J: ALJ Decision | 10/28/2021 | $0.00 | 12/02/2020 | Serious | |
| Penalty | C: Contested | 11/20/2020 | $0.00 | 12/02/2020 | Serious | |
| Penalty | Z: Issued | 10/14/2020 | $0.00 | 12/02/2020 | Serious |
Text For Citation: 01 Item/Group: 001B Hazard:
29 CFR 1910.147(d)(3): All energy isolating devices that were needed to control the energy to the machine or equipment were not physically located and operated in such a manner as to isolate the machine or equipment from the energy source(s): During preventative maintenance planned lubrication of the drive chain to the S2 packaging conveyor, after the guard was removed, the machine was not turned off and unplugged for lubrication. Abatement documentation is required for this violation.