Violation Detail
Standard Cited: 19260703 D01 Requirements for cast-in-place Concrete.
Inspection Nr: 1490905.015
Citation: 01001
Citation Type: Other
Abatement Date: 10/30/2020 2
Initial Penalty: $8,675.00
Current Penalty: $8,675.00
Issuance Date: 10/16/2020
Nr Instances: 1
Nr Exposed: 3
Related Event Code (REC): R
Gravity: 5
Report ID: 0523300
Contest Date: 11/09/2020
Final Order: 04/16/2021
Emphasis:
| Type | Latest Event | Event Date | Penalty | Abatement Due Date | Citation Type | Failure to Abate Inspection |
|---|---|---|---|---|---|---|
| Penalty | F: Formal Settlement | 04/16/2021 | $8,675.00 | 10/30/2020 | Other | |
| Penalty | C: Contested | 12/02/2020 | $8,675.00 | 10/30/2020 | Serious | |
| Penalty | Z: Issued | 10/16/2020 | $8,675.00 | 10/30/2020 | Serious |
Text For Citation: 01 Item/Group: 001 Hazard:
29 CFR 1926.703(d)(1): Reinforcing steel for walls, piers, columns, and similar vertical structures was not adequately supported to prevent overturning and to prevent collapse. a) On or about August 31, 2020, at the previously addressed job site, employees installing pre-tied steel wall curtains were doing so without the steel walls adequately supported exposing employees to hazards associated with the walls overturning. Abatement certification is required for this item in accordance with the requirements of 29 CFR 1903.19(c).
Translate