Violation Detail
Standard Cited: 19100219 H01 Mechanical power-transmission apparatus.
Inspection Nr: 1489017.015
Citation: 01001
Citation Type: Serious
Abatement Date: 09/22/2020 2
Initial Penalty: $4,048.00
Current Penalty: $4,048.00
Issuance Date: 09/16/2020
Nr Instances: 1
Nr Exposed: 1
Related Event Code (REC): R
Gravity: 10
Report ID: 0317500
Contest Date:
Final Order: 10/14/2020
Emphasis:
| Type | Latest Event | Event Date | Penalty | Abatement Due Date | Citation Type | Failure to Abate Inspection |
|---|---|---|---|---|---|---|
| Penalty | Z: Issued | 09/16/2020 | $4,048.00 | 09/22/2020 | Serious |
Text For Citation: 01 Item/Group: 001 Hazard:
29 CFR 1910.219(h)(1): Projecting key(s), setscrew(s), or other projections in revolving part(s) were not removed, made flush, or guarded by metal cover(s): (a) Facility, 618 Canal Street, Williamsburg, PA: On or about August 17, 2020 the rotating shaft on the blue AGCO portable auger had protruding bolts that were not flush or guarded by metal covers. An employee sustained injuries to the groin area when their clothes became caught on a protruding bolt and wound around the shaft pulling the employee into it until the clothing was ripped off and the employee was freed.
Translate