Violation Detail
Standard Cited: 19100147 C04 II D The control of hazardous energy (lockout/tagout).
Inspection Nr: 1483162.015
Citation: 01001A
Citation Type: Serious
Abatement Date: 06/30/2021 2
Initial Penalty: $8,193.00
Current Penalty: $6,100.00
Issuance Date: 11/27/2020
Nr Instances: 1
Nr Exposed: 2
Related Event Code (REC):
Gravity: 5
Report ID: 0523400
Contest Date:
Final Order: 01/05/2021
Emphasis:
| Type | Latest Event | Event Date | Penalty | Abatement Due Date | Citation Type | Failure to Abate Inspection |
|---|---|---|---|---|---|---|
| Penalty | I: Informal Settlement | 01/05/2021 | $6,100.00 | 06/30/2021 | Serious | |
| Penalty | Z: Issued | 11/27/2020 | $8,193.00 | 12/23/2020 | Serious |
Text For Citation: 01 Item/Group: 001A Hazard:
29 CFR 1910.147(c)(4)(ii)(D): The energy control procedures did not clearly and specifically outline the requirements for testing a machine or equipment to determine and verify the effectiveness of lockout devices, tagout devices, and other energy control: (a) On or about July 9, 2020, at the worksite located at W227 N6088 Sussex Rd., Sussex WI, the employer did not ensure that hazardous energy control procedures for the extruder # 2 machine outlined the requirements for verifying the de-energized state and rendering potentially hazardous stored energy safe, thereby exposing workers to caught-in-between and struck-by hazards.