Violation Detail
Standard Cited: 19100147 F01 IV The control of hazardous energy (lockout/tagout).
Inspection Nr: 1482120.015
Citation: 01002
Citation Type: Serious
Abatement Date: 02/16/2021 2
Initial Penalty: $13,494.00
Current Penalty: $10,000.00
Issuance Date: 12/17/2020
Nr Instances: 1
Nr Exposed: 1
Related Event Code (REC): R
Gravity: 10
Report ID: 0521700
Contest Date:
Final Order: 01/20/2021
Emphasis:
| Type | Latest Event | Event Date | Penalty | Abatement Due Date | Citation Type | Failure to Abate Inspection |
|---|---|---|---|---|---|---|
| Penalty | I: Informal Settlement | 01/20/2021 | $10,000.00 | 02/16/2021 | Serious | |
| Penalty | Z: Issued | 12/17/2020 | $13,494.00 | 12/30/2020 | Serious |
Text For Citation: 01 Item/Group: 002 Hazard:
1910.147(f)(1)(iv): Deenergize all systems and reapply energy control measures i accordance with paragraph (d) of this section to continue the servicing and/or maintenance: a) Seasoned Cooked Beef Department - On or about July 1, 2020, an employee was exposed to machine hazards associated with rotating blades inside a tube when, after troubleshooting the lack of product flow, the SCB Packoff Supply Pump model 0300 TRAIO, serial number 262987/a/17, was not deenergized in accordance with the employer's written procedure and energy control measures were not reapplied before the employee used a gloved finger in an attempt to unjam the inside of the SCB Packoff Supply Pump, which resulted in the amputation of the tip of the employee's right index finger.
Translate