Violation Detail
Standard Cited: 19100217 B07 IV B Mechanical power presses.
Inspection Nr: 1478350.015
Citation: 01002B
Citation Type: Serious
Abatement Date: 04/30/2021 2
Initial Penalty: $0.00
Current Penalty: $0.00
Issuance Date: 09/09/2020
Nr Instances: 1
Nr Exposed: 2
Related Event Code (REC):
Gravity: 5
Report ID: 0112000
Contest Date:
Final Order: 10/09/2020
Emphasis:
| Type | Latest Event | Event Date | Penalty | Abatement Due Date | Citation Type | Failure to Abate Inspection |
|---|---|---|---|---|---|---|
| Penalty | P: Petition to Mod Abatement | 12/31/2020 | $0.00 | 04/30/2021 | Serious | |
| Penalty | I: Informal Settlement | 10/09/2020 | $0.00 | 12/31/2020 | Serious | |
| Penalty | Z: Issued | 09/09/2020 | $0.00 | 10/27/2020 | Serious |
Text For Citation: 01 Item/Group: 002B Hazard:
29 CFR 1910.217(b)(7)(iv)(b): The "inch" single control was protected against accidental operation and was not located so that the worker cannot reach into the point of operation while operating the single control: 400 Riverside Avenue, Bristol, Connecticut: On, or about, July 16, 2020, Press #117, a Bliss partial revolution mechanical power presses was provided with a single inch/run button that was not ringed or otherwise protected against accidental operation and was located within reach of the point of operation.