Violation Detail
Standard Cited: 19100219 C02 I Mechanical power-transmission apparatus.
Inspection Nr: 1477747.015
Citation: 01002A
Citation Type: Serious
Abatement Date: 07/17/2020 2
Initial Penalty: $6,747.00
Current Penalty: $4,300.00
Issuance Date: 06/25/2020
Nr Instances: 1
Nr Exposed: 2
Related Event Code (REC):
Gravity: 5
Report ID: 0523900
Contest Date:
Final Order: 07/15/2020
Emphasis:
| Type | Latest Event | Event Date | Penalty | Abatement Due Date | Citation Type | Failure to Abate Inspection |
|---|---|---|---|---|---|---|
| Penalty | I: Informal Settlement | 07/15/2020 | $4,300.00 | 07/17/2020 | Serious | |
| Penalty | Z: Issued | 06/25/2020 | $6,747.00 | 07/17/2020 | Serious |
Text For Citation: 01 Item/Group: 002A Hazard:
29 CFR 1910.219(c)(2)(i): All exposed part(s) of horizontal shafting seven (7) feet or less from floor or working platform were not protected by stationary casing(s) enclosing shafting completely or by trough(s) enclosing sides and top or sides and bottom of shafting: (a) 1300 Odanah Road, Medalist Challoner 900 double-ended tenoner machine; The horizontal driveshaft for the machines feed mechanism was not adequately protected by stationary casing(s) to completely enclose the shafting or by trough(s) to enclose the sides and top or sides and bottom of the shafting.