Violation Detail
Standard Cited: 19100213 F01 Woodworking machinery requirements.
Inspection Nr: 1477118.015
Citation: 01001
Citation Type: Serious
Abatement Date: 07/28/2020 2
Initial Penalty: $9,446.00
Current Penalty: $4,723.00
Issuance Date: 07/09/2020
Nr Instances: 1
Nr Exposed: 5
Related Event Code (REC):
Gravity: 10
Report ID: 0522500
Contest Date:
Final Order: 07/22/2020
Emphasis:
| Type | Latest Event | Event Date | Penalty | Abatement Due Date | Citation Type | Failure to Abate Inspection |
|---|---|---|---|---|---|---|
| Penalty | I: Informal Settlement | 07/22/2020 | $4,723.00 | 07/28/2020 | Serious | |
| Penalty | Z: Issued | 07/09/2020 | $9,446.00 | 07/28/2020 | Serious |
Text For Citation: 01 Item/Group: 001 Hazard:
29 CFR 1910.213(f)(1): Feed rolls and saws shall be protected by a hood or guard to prevent the hands of the operator from coming in contact with the in-running rolls at any point. The guard shall be constructed of heavy material, preferably metal, and the bottom of the guard shall come down to within three-eighths inch of the plane formed by the bottom or working surfaces of the feed rolls. This distance (three-eighths inch) may be increased to three-fourths inch, provided the lead edge of the hood is extended to be not less than 5 1/2 inches in front of the nip point between the front roll and the work. a. On or about May 27, 2020, the blade of the long board trim saw located in the saw shop was not adequately guarded, which resulted in an amputation injury.
Translate