Violation Detail
Standard Cited: 19100147 D The control of hazardous energy (lockout/tagout).
Inspection Nr: 1476798.015
Citation: 01001
Citation Type: Serious
Abatement Date: 09/04/2020 2
Initial Penalty: $9,446.00
Current Penalty: $4,723.00
Issuance Date: 07/01/2020
Nr Instances: 5
Nr Exposed: 20
Related Event Code (REC): A;R
Gravity: 10
Report ID: 0522000
Contest Date:
Final Order: 07/21/2020
Emphasis:
| Type | Latest Event | Event Date | Penalty | Abatement Due Date | Citation Type | Failure to Abate Inspection |
|---|---|---|---|---|---|---|
| Penalty | I: Informal Settlement | 07/21/2020 | $4,723.00 | 09/04/2020 | Serious | |
| Penalty | Z: Issued | 07/01/2020 | $9,446.00 | 08/04/2020 | Serious |
Text For Citation: 01 Item/Group: 001 Hazard:
29 CFR 1910.147(d): Application of control. The established procedures for the application of energy control (the lockout or tagout procedures) shall cover the following elements and actions and shall be done in the following sequence: a) On May 27, 2020, the employer did not develop procedures for the control of potentially hazardous energy when employees were engaged in activities such as adjusting the guillotine knife on equipment such as but not limited to the six rubber extrusion lines.