Violation Detail
Standard Cited: 19100212 A03 II General requirements for all machines.
Inspection Nr: 1474596.015
Citation: 01002
Citation Type: Serious
Abatement Date: 08/14/2020
Initial Penalty: $8,501.00
Current Penalty: $8,501.00
Issuance Date: 07/14/2020
Nr Instances: 1
Nr Exposed: 1
Related Event Code (REC): R
Gravity: 10
Report ID: 0215800
Contest Date: 08/04/2020
Final Order:
Emphasis:
| Type | Latest Event | Event Date | Penalty | Abatement Due Date | Citation Type | Failure to Abate Inspection |
|---|---|---|---|---|---|---|
| Penalty | C: Contested | 08/05/2020 | $8,501.00 | 08/14/2020 | Serious | |
| Penalty | Z: Issued | 07/14/2020 | $8,501.00 | 08/14/2020 | Serious |
Text For Citation: 01 Item/Group: 002 Hazard:
29 CFR 1910.212(a)(3)(ii): Point(s) of operation of machinery were not guarded to prevent employee(s) from having any part of their body in the danger zone(s) during operating cycle(s): a. In the production area, breast room, on or about 4/22/2020: The point of operation on the MultiVac machine, model R126, serial number 140334, was not adequately guarded at the discharge chute to prevent employees from having any part of their body in the danger zone during operation.