Violation Detail
Standard Cited: 19100147 D The control of hazardous energy (lockout/tagout).
Inspection Nr: 1469295.015
Citation: 01002A
Citation Type: Serious
Abatement Date: 06/25/2020 2
Initial Penalty: $13,494.00
Current Penalty: $6,747.00
Issuance Date: 06/02/2020
Nr Instances: 1
Nr Exposed: 4
Related Event Code (REC):
Gravity: 10
Report ID: 0524700
Contest Date:
Final Order: 06/23/2020
Emphasis:
| Type | Latest Event | Event Date | Penalty | Abatement Due Date | Citation Type | Failure to Abate Inspection |
|---|---|---|---|---|---|---|
| Penalty | I: Informal Settlement | 06/23/2020 | $6,747.00 | 06/25/2020 | Serious | |
| Penalty | Z: Issued | 06/02/2020 | $13,494.00 | 06/25/2020 | Serious |
Text For Citation: 01 Item/Group: 002A Hazard:
29 CFR 1910.147(d): The established procedure for the application of energy control (the lockout or tagout procedures) did not cover the actions listed in and was not done in sequence as required by 29 CFR 1910.147(d)(1)-(6): a. Tronair Inc., on or about March 12, 2020, at the address of 1 Air Cargo Parkway East, Swanton, Ohio 43558: The employer did not ensure employees performing blade changes on a Amanda band saw utilized Specific Energy Control application steps for energy isolation. An operator was exposed to amputation hazards while changing blades on the band saw. As a result, the remaining applicable energy control elements, involving machine isolation [1910.147(d)(3)], lockout/tag-out device application [1910.147(d)(4)], dissipation of residual energy [1910.147(d)(5)(i)], and verification of isolation [1910.147(d)(6)] were not implemented to protect employees from machine servicing hazards.
Translate